ND-70348 (E) CHAPTER 4
Page 598
Revision 3.0
ALPE
ALPE: Assignment of Line Privacy Expansion Data
1. General
This command is used to assign the eight-party Conference Trunk (CFT card), which is seized in Line Privacy
Expansion Service on a per-tenant basis.
2. Precautions
1. Enter the data “1” at the TN parameter when “1” is entered at the TNF parameter.
2. The applicable tenant number (TN) range is designated by the ASYD command, SYS 1, INDEX 8.
3. The Station Number entered in the STN parameter must correspond to the one assigned at the first circuit
(No.0 circuit) of the CFT card.
3. Data Entry Instructions
TENANT FLAG
(TNF)
0/1
TENANT NUMBER
(TN)
STATION NUMBER
(STN)
REMARKS
1
1311
2
TNF
0 = Separate
1 = Common