ND-70348 (E) CHAPTER 4
Page 637
Revision 3.0
AFRT
AFRT: Assignment of FCCH Controlled Connection Route Data for LDM
1. General
This command is used to assign the connection route controlling connection trunks for each FCCH number.
2. Precautions
1. Before executing this command, confirm that the following assignments have already been completed:
(a) The FCCH number has been assigned by the AFCH command.
(b) The Connection Route data has been assigned by the ACRD command.
2. The maximum of alternative connection routes for 1 FCHN (FCCH No.) is 8.
3. For more detailed information, see the “Netfusing System Manual”.
3. Data Entry Instructions
FCCH NUMBER (FCHN)
1-255
FCHN
A unique number allocated to
the FCH card at each node
C_RT
Connection Route assigned for B-channel
by the ACRT command.
CONNECTION ROUTE (C_RT) 1-1023
1234 5678