ND-70348 (E) CHAPTER 4
Page 486
Revision 5.0
ADPCL
ADPCL: Assignment of Determinate Point Code Data for LDM
1. General
This command is used to assign the destination Point Code (PC) for CCIS interface. This data is written in Local
Data Memory (LDM).
2. Precautions
1. A unique PC must be given to a node in the CCIS network. The OPC (Originating Point Code ) is desig-
nated by the ASYD command, SYS1, INDEX180 and 181.
2. The PC is the decimal value from 1 to 16367 in CCIS network.
3. An arbitrary PC may be assigned for the ISDN interface, unless the PC is duplicated in the CCIS network.
4. The PC assigned by this command should correspond to the one assigned by the ACIC1/ACIC2 command.
3. Data Entry Instructions
For CCIS, assign the Logical route number of speech route.
LOGICAL ROUTE NUMBER
(LGRT) 1-899
DETERMINATE POINT
CODE (PC) 1-16383
REMARKS
For CCIS, enter the PC of destination node.
PC
LRGT