ND-70348 (E) CHAPTER 4
Page 322
Revision 3.0
ASTN
ASTN: Assignment of Station Number
1. General
This command is used to change the physical station number assigned to a particular LEN.
2. Precautions
1. The primary digit, the number of digits and the kind of service (SRV=STN) which designated by the ANPD
and ASPA command affect the new station number. Hence, the new station number must be assigned ac-
cording to the numbering plan data.
2. The number of station number (STN) digits are designated by the ASYD command, SYS1, INDEX16.
3. This command can be used only when the station to be changed its number is in idle status.
4. Update the station number changed in this command to the sheet in the ASDT command.
3. Data Entry Instructions
OLD STATION NUMBER
(STN)
NEW STATION NUMBER
(NEW STN)
REMARKS
TENANT
NUMBER
(TN)
NEW STN
Enter the new station number corresponding
to the existing numbering plan.
STN
The station number has been
assigned by the ASDT command.