ND-70348 (E) CHAPTER 4
Page 556
Revision 3.0
ANPT
ANPT: Assignment of Numbering Data for PTT Network
1. General
This command is used to assign Numbering Data for PTT Network programming.
2. Precautions
This command is not available for Australia.
3. Data Entry Instructions
SELECTION SIGNAL CODE
(DC)
Max. 32 Digits
TYPE
1-6
KC SIGNAL
INPUT
POSITION
(KCP)
1-32
KCP
This parameter appeas only
when TYPE=5.
TYPE
1 = Local Call
2 = Local Special Call
3 = Toll Operator Call
4 = Overseas Operator Call
5 = Toll Call
6 = Overseas Call