ND-70348 (E) CHAPTER 4
Page 786
Revision 3.0
AAST
AAST: Assignment of Administration Station Data
1. General
This command is used to assign and delete the administration station data.
2. Precautions
1. This command is used for the Hotel Application only.
2. The AASN command is used to change the station number, and the AACL command is used to change the
Class data (TEC, RSC, SFC etc.).
3. Assignment of Room Class 15 is not available.
4. The number of digits for a station number are designated by the ASYD command, SYS1, INDEX 16.
The maximum number of digits for a station is 6.
5. The first digit of the station number is designated by the AANP command.
6. The RSC and SFC data work in conjunction with ARSC/ASCR/ADNR and ASFC commands.