ND-70348 (E) CHAPTER 4
Page 562
Revision 3.0
ASLU1
ASLU1: Assignment of Slumber Time Data 1
1. General
This command is used to assign the data related to the Slumber Time - Do Not Disturb service feature.
2. Precautions
1. The call terminating to the slumber group is forwarded to an Attendant Console or an Announcement trunk
(DAT circuit card) with a predetermined slumber time.
2. The station numbers belonging to the slumber group are assigned by ASLU1 command.
3. The slumber time period and the forwarded destination are assigned by the ASLU2 command.
4. The G parameter on this command is an intermediate data to assign the ASLU2 command.
5. Denial of the Slumber Time - Do Not Disturb service feature can be assigned by the following commands:
(a) ARTD command, SLOV=1 is assigned for trunk route
or
(b) ASFC command SFI=107, RES=1 is assigned for the class of the originating station
3. Data Entry Instructions
STATION NUMBER
(STN)
SLUMBER
GROUP
NUMBER(G)
1-7
REMARKS
TENANT
NUMBER
(TN)
G
Enter data in the G parameter. Multiple numbers of
STN can be assigned to a slumber group number
STN
Enter the station number of the slumber
group.