Loading...
ND-70348 (E) CHAPTER 4
Page 475
Revision 3.0
APAD
APAD: Assignment of PAD Data
1. General
This command is used to assign PAD control data for tandem connections, and trunk to station connections.
2. Precautions
When KIND = S (Station) is designated, assign the dummy data to the parameter “OGPAD”.
3. Data Entry Instructions
The kinds of connection entering
in this parameter are as follows.
T=Tandem Connection
S=Station
O=Outgoing (Not used)
I=Incoming (Not used)
1 9 1 1
1 1 4 81
0 0
2
KIND
The assignment of this parameter
is required only when KIND=O
(Outgoing) is designated.
This data should be assigned by
the AMND command.
DC
0=No APAD Setting
1-14=Note1 15=PAD OFF (0dB)
ICPAD/OGPAD
This parameter is not required for the
parameter KIND=T (Tandem Connec-
tion).
ICPAD is not required when
assigning KIND as O (Outgoing).
SFC
KIND
OF
CONNEC
-TION
(KIND)
T/S/O/I
INCOMING
ROUTE
NUMBER
(ICRT)
OUTGOING
ROUTE
NUMBER
(OGRT)
SFC
0-15
DIGIT CODE
(DC)
MAXIMUM 24 DIGITS
INCOM-
ING
PAD
DATA
(ICPAD)
1-15
OUTGO-
ING
PAD
DATA
(OGPAD)
1-15
ICPAD
The parameter OGPAD is not required
when assigning KIND as I (Incoming).
OGPAD
Note 1: Switch setting varies depends on the
trunk circuit card. Refer to “Circuit
Card Manual”.

Table of Contents

Related product manuals