ND-70348 (E) CHAPTER 4
Page 527
Revision 3.0
AUCDL
AUCDL: Assignment of UCD Control Data for LDM
1. General
This command assigns the miscellaneous data related to the Uniform Call Distribution (UCD) service feature
for each Node by using Telephone Number. The data is written in Local Data Memory (LDM).
2. Precautions
1. The UCD member station and UCD pilot (controlling station) station should be assigned by the ASHUL
command.
2. This command is used to specify the following UCD related options:
(a) The maximum number of calls in UCD queuing.
(b) The threshold of the UCD Call Waiting Lamp (which is accommodated on a D
term
) starts to flash.
(c) Denial of the MCI call result text of the call terminated to the UCD group.
3. The following data should also be assigned for UCD - Call Waiting lamp flashing:
ASYD command, SYS1, INDEX 61, b5 = 1 (Call Waiting Display-UCD in Service)
AKYD command, FKY = 47 (UCD Call Waiting Lamp)
4. After the data assignment, the line circuit card which contains the UCD group stations must be initialized
(turn the MB key ON/OFF).
5. This command is available since Release 9 software enhancement.