ND-70348 (E) CHAPTER 4
Page 217
Revision 3.0
AUNT
AUNT: Assignment of Unit Data
1. General
This command assigns the Unit data. It also assigns miscellaneous circuit cards to be mounted in LPM.
2. Precautions
Prior to assigning the number of unit data using this command, the ASYD command should be properly as-
signed.
The applicable data range in the Module Group Number (MG) parameter is designated by the ASYD com-
mand, SYS1, INDEX 0
(page 82)
.
Since the PFT is a mechanical action circuit, the PFT operates properly without any data assignment. How-
ever, if the "PFT control by external key" is required, the following data assignments are needed:
(a) AUNT command, TYPE=2 (PFT)
(b) AEKD command
(c) ANCD command
If the number of the unit’s data deletion is required, you should clear all the station/trunk data within the unit
by using the ASDT/ATRK commands.