EasyManuals Logo

NEC NEAX 7400 IMX User Manual

NEC NEAX 7400 IMX
857 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #220 background imageLoading...
Page #220 background image
ND-70348 (E) CHAPTER 4
Page 217
Revision 3.0
AUNT
AUNT: Assignment of Unit Data
1. General
This command assigns the Unit data. It also assigns miscellaneous circuit cards to be mounted in LPM.
2. Precautions
Prior to assigning the number of unit data using this command, the ASYD command should be properly as-
signed.
The applicable data range in the Module Group Number (MG) parameter is designated by the ASYD com-
mand, SYS1, INDEX 0
(page 82)
.
Since the PFT is a mechanical action circuit, the PFT operates properly without any data assignment. How-
ever, if the "PFT control by external key" is required, the following data assignments are needed:
(a) AUNT command, TYPE=2 (PFT)
(b) AEKD command
(c) ANCD command
If the number of the unit’s data deletion is required, you should clear all the station/trunk data within the unit
by using the ASDT/ATRK commands.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NEC NEAX 7400 IMX and is the answer not in the manual?

NEC NEAX 7400 IMX Specifications

General IconGeneral
BrandNEC
ModelNEAX 7400 IMX
CategoryServer
LanguageEnglish

Related product manuals