ND-70348 (E) CHAPTER 4
Page 216
Revision 3.0
ASYDL
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
512-1535
DATA
(DATA)
00 – FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
1
930~933
(For 16-IMG system)
Logical PBI Number of LMG connected to TSW0 in the ISWM.
Note 1: This data is available when SYS1, INDEX929, b0=1 is
assigned.
Note 2: The different FPC can be assigned for 2 Kbps PCM
data transmission at each INDEX.
934~937
(For 16-IMG system)
Logical PBI Number of LMG connected to TSW1 in the ISWM.
Note 1: This data is available when SYS1, INDEX929, b1=1 is
assigned.
Note 2: The different FPC can be assigned for 2 Kbps PCM
data transmission at each INDEX.
938~941
(For 16-IMG system)
Logical PBI Number of LMG connected to TSW2 in the ISWM.
Note 1: This data is available when SYS1, INDEX929, b2=1 is
assigned.
Note 2: The different FPC can be assigned for 2 Kbps PCM
data transmission at each INDEX.
942~945
(For 16-IMG system)
Logical PBI Number of LMG connected to TSW3 in the ISWM.
Note 1: This data is available when SYS1, INDEX929, b3=1 is
assigned.
Note 2: The different FPC can be assigned for 2 Kbps PCM
data transmission at each INDEX.
946
(For 16-IMG system)
PBI No. of the LMG where DLMX card is mounted.
947~960 Not used
961
b
0
~b
3
Message sending cycle to request the state of each IMG.
0 = 2 sec. 1 = 5 sec.
2 = 10 sec. 3 = 30 sec.
4 = 1 min. 5 = 3 min.
6 = 5 min. 7 = 10 min.
8-15 = 2 sec.
b
4
~b
7
Not used
962~1535 Not used