ND-70348 (E) CHAPTER 4
Page 553-1
Revision 5.0
ASGDN
ASGDN : Assignment of Special Group Data for NDM
1. General
This command is used to assign the stations which belong to the special group applied to the following service
features in Netfusing:
Off Hook Alarm
Priority Call
The member stations are specified by Telephone Number previously assigned by the ALGSN command. The
data assigned by this command is written in the Network Data Memory (NDM) of the Network Control Node
(NCN), updating the NDM at each Local Node (LN).
2. Precautions
1. The call destination of the special group is designated by the ASIDN command.
2. Since the GN parameter is intermediate data to the ASIDN command, enter a unique number for each spe-
cial group.
3. This command is available since Release 11 software enhancement.
3. Data Entry Instructions
TELN
Enter the Telephone Number
of the station which belongs to
the special group.
GN
Enter a unique Group Number for
each special group.
USER
GROUP
NUMBER
(UGN)
TELEPHONE NUMBER
(TELN)
Max. 16 digits
FUNCTION
NUMBER
(F)
0-7
GROUP
NUMBER
(GN)
1-255
REMARKS
F
4=Priority Call 1
5=Priority Call 2
6=Priority Call 3
7=Not used
0=Off Hook Alarm
1=Not used
2=Not used
3=Not used