ND-70348 (E) CHAPTER 4
Page 802
Revision 3.0
Printed in Japan
0103
ASPF
ASPF: Assignment of Special Access Code Floor
1. General
This command is used to assign Floor Data for the Access Code of the Floor Service.
2. Precautions
1. This command is used for the Hotel Application only.
2. When assigning data by this command, the ASYD command, SYS 1, INDEX 165, bit7 = 1 (Floor Service
is provided) must have been assigned.
3. When assigning data by this command, the Access Code for Floor Service must have been assigned by the
AASP/AGSP command, SSC=2, SID 56.
4. When deleting data for this command, the Access Code for Floor Service must be deleted in advance by
the AASP/AGSP command.
3. Data Entry Instructions
D/N
ANX
FLR
NO.
G
DC
D : Day Mode
N : Night Mode
CALLED PARTY
INFORMATION
CALLING PARTY INFORMATION
CALLED
NUMBER
(DC)
Max. 6 digits
DAY/
NIGHT
MODE
(D/N)
D/N
TENANT
NUMBER
(TN)
SERVICE
INDEX
NUMBER
(NO.) 0-15
ANNEX
(ANX)
0-3
GROUND
FLOOR AND
ABOVE/
BELOW
(G)
0/1
FLOOR
NUMBER
(FLR)1-127
0 : Main Building
1 : Annex 1
2 : Annex 2
3 : Annex 3
Floor Number (1-127)
Enter SERVICE INDEX NUMBER
(NO.) assigned in the AASP/AGSP
command.
Ground/Underground
0 : Ground
1 : Underground
Enter the called number such as a station
number.