ND-70348 (E) CHAPTER 4
Page 326
Revision 3.0
APHN
APHN: Assignment of Phantom Station Number
1. General
This command is used to assign a phantom number for a station.
2. Precautions
1. Numbers that are being used as station or LDN numbers cannot be used as phantom numbers.
2. When an incoming call is terminated to a phantom number, either no station hunting or station hunting de-
pending on the data in the PH parameter is performed if the called station is a member station of a hunt
group.
3. A maximum of five phantom numbers can be assigned to a station. (Including individual phantom number
and phantom number in a hunting group.)
4. The applicable tenant number (TN) range is designated by the ASYD command, SYS1, INDEX8.
5. Data entry is not required in the parameters “MODE” and “STN”, since data that has already been assigned
is displayed.