ND-70348 (E) CHAPTER 4
Page 327
Revision 3.0
APHN
3. Data Entry Instructions
REAL
STATION
NUMBER
(REAL
STN)
HUNTING
CONDITION
OF
PHANTOM
NUMBER
(PH) 0/1
TENANT
NUMBER
(TN)
PHANTOM STATION NUMBER (PHSTN)
REAL STN
Enter a station number
PHSTN
A maximum of 5 phantom
station numbers can be
assigned for a real station.
PH
0= Individual Phantom Number
1= Phantom Number in a Hunting Group
REAL STN
The station number of the group
designated in the parameter “MODE”
0= Individual Phantom Number
1= Phantom Number in a Hunting Group
CNT = 1 PH CNT = 2 PH CNT = 3 PH CNT = 4 PH CNT = 5
1 25645 1 300 1 301 1 302 0 303 0 304
REAL
STATION
NUMBER
(REAL STN)
MODE OF
REAL OR
PHANTOM
(MODE) 1/2
TENAT
NIMBER
(TN)
STATION
NIMBER
(STN)
HUNTING
CONDITION OF
PHANTOM
NUMBER
(PH) 0/1
PHANTOM STATION NUMBER (PHSTN)
MODE
This data determines how to develop the
station + phantom station group.
1 = Real Mode 2 = Phantom Mode
STN
The station number which is designated in the parameter “MODE”.
This data is required to specify the group.
Example:
When MODE = 1 is designated, assign the real station number.
When MODE = 2 is designated, assign the phantom station number.
PHSTN
A maximum of 5 phantom stations can be
assigned for a real station number.
CNT = 1 PH CNT = 2 PH CNT = 3 PH CNT = 4 PH CNT = 5
25645 1 300 1 301 1 302 0 303 0 304
Assignment
Display
1 1 25645
PH

Table of Contents

Related product manuals