ND-70348 (E) CHAPTER 4
Page 474
Revision 3.0
ACID
Day/Night
(D/N)
D/N
Ringer
Pattern
(RGP)
0/1/5/6/7
Service
Kind 2
(SRV2)
1/2
Call Connecting
Index (CFI)
1-3
Tenant Number for
Call Connecting
(CFI-TN)
Station Number for
Call Connecting
(CFI-STN)
Abbreviated Digit
Code for Call Connecting
(ADC) 4 digits
1 = Attendant Console
2 = Station
3 = Outside
Caller ID
(CID)
1-28
CFI
SRV2
1 = Dial in
2 = C.O. connection restriction
RT
When TYPE=2 (Dial-in, C.O. connect restriction) is assigned
Input Type
(TYPE)
2
RGP
This parameter appears
when SRV1 = 6.
This parameter appears when CFI=3.
ADC
These parameters appear when CFI=2.
CFI-TN/CFI-STN
Service
Kind 3
(SRV3)
Caller ID
(CID)
1-28
SRV3
1 = Calling Party Number
Representation Name
(NAME)
24 digits at maximum
When TYPE=3 (Calling Party Number - Name Assignment and Display) is assigned
Input Type
(TYPE)
3
1
Enter the desired name against
the calling number (CID).
NAME

Table of Contents