ND-70348 (E) CHAPTER 4
Page 130
Revision 3.0
ASYD
SYSTEM
DATA
TYPE (SYS)
SYSTEM
DATA INDEX
(INDEX)
0 – 511
DATA
(DATA)
00 – FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
1
129
b
0
Register Inter Digit Timer:
Miscellaneous Timer Counter
(MTC) is to be assigned a value
from 0 Hex to F Hex (0-15).
The interval between
dialed digits.
Timer Value Setting is
MTC × 2 sec.
Note: When this
data is 00
Hex, default
data is auto-
matically set
to 6 sec.
b
1
b
2
b
3
0
b
4
Not used
0
b
5
0
b
6
0
b
7
130
b
0
Sender Connection Acknowledg-
ment Timer:
Miscellaneous Timer Counter
(MTC) is to be assigned a value
from 0 Hex to F Hex (0-15).
For calls over sender-
ized Tie Lines, the
sender requires an
ACK signal from the
distant PBX before it
can send digits. This
timer specifies how
long the sender must
wait.
Timer Value Setting is
MTC × 2 sec.
Note: When this
data is 00
Hex, default
data is auto-
matically set
to 4 sec.
b
1
b
2
b
3
0
b
4
Not used
0
b
5
0
b
6
0
b
7
ORT SEIZURE
DIAL PULSE
“3” “2”
OGT START
WINK SIGNAL

Table of Contents