EasyManua.ls Logo

NEC NEAX 7400 IMX - Page 140

NEC NEAX 7400 IMX
857 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ND-70348 (E) CHAPTER 4
Page 138
Revision 3.0
ASYD
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
0 – 511
DATA
(DATA)
00 – FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
1
145
b
0
Attendant Console Automatic Recall
Timer:
Miscellaneous Timer Counter (MTC)
is to be assigned a value from 0 Hex
to F Hex (0-15).
This timer assigns the
duration for which a
call being transferred
to a station from the
attendant will ring at
the station before be-
ing recalled.
Timer Value Setting is
MTC × TC sec.
Note: When this
data is 00
Hex, default
data is auto-
matically set
to 32 sec.
b
1
b
2
b
3
1
b
4
Timer Class (TC) must be assigned as
“001”
TC = 001 means 8 sec.
0
b
5
0
b
6
b
7
Attendant Console Automatic Recall
Timer Value
0/1 = Ineffective/Effective
146
b
0
Howler Tone Timer:
Miscellaneous Timer Counter (MTC)
is to be assigned a value from 0 Hex
to F Hex (0-15).
This timer assigns the
duration between
tones when Howler
Tone is being sent to a
station.
Timer Value Setting is
MTC × TC.
The Interval Pattern is
assigned in INDEX
64, b
3
and b
4
Note: When this
data is 00
Hex, default
data is auto-
matically set
to 30 sec.
b
1
b
2
b
3
b
4
Timer Class (TC) is to be assigned
one of the following values:
b
5
b
6
0
b
7
Not used
HOWLER TONE
b
6
b
5
b
4
b
6
b
5
b
4
000 = 100=
001 = 101=
010 = 110=
0 1 1 = 2 sec. 1 1 1 =

Table of Contents

Related product manuals