ND-70348 (E) CHAPTER 4
Page 140
Revision 3.0
ASYD
SYSTEM
DATA
TYPE (SYS)
SYSTEM
DATA
INDEX
(INDEX)
0 – 511
DATA
(DATA)
00 – FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
1
150
b
0
SHF Sending Guard Timer for CAS-
Main Station:
Miscellaneous Timer Counter (MTC)
is to be assigned a value from 0 Hex to
F Hex (0-15).
The length of time
the attendant must
wait before trans-
ferring a call to the
Satellite PBX after
making a switch
hook flash. Timer
Value Setting is
MTC
× TC sec.
Note: When this
data is 00
Hex, de-
fault data
is auto-
matically
set from
960-1024
msec.
b
1
b
2
b
3
b
4
Timer Class (TC) is to be assigned one
of the following values:
b
5
b
6
0
b
7
Not used
151
b
0
SHF length for a CAS Main Station:
Miscellaneous Timer Counter (MTC)
is to be assigned a value from 00 Hex
to 1F Hex (0-31).
The length of an
SHF signal being
sent from the Main
to a Satellite PBX.
Timer Value Setting
is MTC × 32 msec.
(MTC+1) × 32
msec.
Note: When this
data is 00
Hex, de-
fault data
is auto-
matically
set from
448 msec.-
480 msec.
b
1
b
2
b
3
b
4
0
b
5
Not used
0
b
6
0
b
7
b
6
0
0
0
0
b
5
0
0
1
1
b
4
0
1
0
1
=–
=–
=–
= 2 sec.
b
6
1
1
1
1
b
5
0
0
1
1
b
4
0
1
0
1
=–
=–
=–
=–
LENGTH
SHF