ND-70348 (E) CHAPTER 4
Page 148
Revision 3.0
ASYD
Note: Guest Station is available. Admin. Station is only SST.
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
0 – 511
DATA
(DATA)
00 – FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
1
162
b
0
Destination of call when a call between guest stations is
restricted.
b
1
b
0
b
1
b
0
0 0 = ROT 1 0 = Announcement
01=ATT 11=
(for Hotel sys-
tem)
b
1
b
2
Destination of call when Room Cutoff is assigned.
b
3
b
2
b
3
b
2
0 0 = ROT 1 0 = Announcement
01=ATT 11=
b
3
b
4
Destination of call when Do Not Disturb is assigned.
b
5
b
4
b
5
b
4
0 0 = ROT 1 0 = Announcement
01=ATT 11=
b
5
b
6
Tone to be given when Timed Reminder / a wake-up call is answered.
b
7
b
6
b
7
b
6
0 0 = Music On Hold 1 0 =
0 1 = Announcement 1 1 =
b
7
163
b
0
Overtime Call timer.
b
1
b
0
b
1
b
0
0 0 = 30 min. 1 0 = 90 min.
0 1 = 60 min. 1 1 = 120 min.
(for Hotel sys-
tem)
b
1
b
2
Overtime Call 0/1 = Out/In Service
b
3
Overtime Call indication
0/1 = On Attendant Console/Hotel Printer
b
4
Step Call from Guest Station is allowed
0/1 = Out Service/In
b
5
Tone type for Maid Dialing Note
b
6
b
5
b
6
b
5
0 0 = SST 1 0 = Music on Hold
0 1 = Announcement 1 1 = Music on Hold
b
6
b
7
Start time for Timed Reminder/Wake-Up Call
0/1 = On time/5 min. earlier than the appointed time