ND-70348 (E) CHAPTER 4
Page 158
Revision 3.0
ASYD
SYSTEM
DATA
TYPE (SYS)
SYSTEM
DATA
INDEX
(INDEX)
0 – 511
DATA
(DATA)
00 – FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
1
186
b
0
0/1 = Link Reconnection Not Involved/Link Reconnection
Involved
Note: An Interoffice transfer service is available. For
example, with No. 7 CCIS, a caller has called out-
side their own office but is actually talking with
somebody in their own office. This bit is used to
reconfigure links so they are not wasted in call
transfer service.
b
1
Restriction check based on the caller’s restriction class
when the outgoing trunk is using the No. 7 CCIS in a tan-
dem connection.
0/1 = No Check/Check
0
b
2
0/1 = –/No. 7 CCIS Loop–Back Test in progress
0
b
3
Not used
b
4
Serial Call-Loop Release
0/1 = Out/In Service
b
5
Clearing of the buffer memory for use in the centralized
management report (for CCIS).
0/1 = not necessary/necessary
b
6
CCIS or ISDN
0/1 = Out/In Service
b
7
Centralized Billing Office Code
0/1 = Ineffective/Effective
187 00
Data Bus used for CCH/DCH cards
0/1 = PM Bus/ISDN Bus