ND-70348 (E) CHAPTER 4
Page 170
Revision 3.0
ASYD
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
0 – 511
DATA
(DATA)
00 – FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
1
242
b
0
Miscellaneous Timer Counter (MTC)
is to be assigned a value from 0 Hex
to F Hex (0 – 15).
Timer for Delay An-
nouncement – Attendant
(Duration of RBT)
Timer Value Setting is
MTC x TC sec.
Note: When this data is
00 Hex, default
data is automati-
cally set to 30 sec.
b
1
b
2
b
3
b
4
Timer Class (TC) is to be assigned
one of the following values:
b
6
b
5
b
4
b
6
b
5
b
4
000 = 100=
001 = 101=
010 = 110=
0 1 1 = 2 sec. 1 1 1 =
b
5
b
6
0
b
7
Not used
243
b
0
Miscellaneous Timer Counter (MTC)
is to be assigned a value from 0 Hex
to F Hex (0~15).
Timer for the forced re-
lease for a tandem con-
nection in Remote
Access to System.
When OG trunk cannot
receive Answer Signal
from the destination, An-
swer Signal is sent when
this timer expires.
Timer Value Setting is
MTC x TC sec.
Note 1:When this data is
00 Hex, default
data is automati-
cally set to 64 sec.
b
1
b
2
b
3
b
4
Timer Class (TC) is to be assigned
one of the following values:
b
5
b
6
0b
7
Not used
244
b
0
Answer by Radio Paging answer code.
0/1 = Out/In Service
Note: This bit is valid when SYS-1, INDEX 73, Bit 4 is 1 (= Sta-
tion Number is Automatically sent).
0b
1
Not used
b
2
MCI-CCIS output packet change when the last digit is “*”
0/1 = -/route number and trunk number are output
0b
3
~
b
4
Not used
b
5
Timing of providing the announcement for Delay Announcement –
Attendant
0 = immediately after the call termination
1 = after the Ring Back Tone (SYS1, INDEX 242)
b
6
Hooking operation during 3-party conference call
0/1 = -/Hooking operation is invalid
Note: This data is available for software Release 9 or later.
0b
7
Not used
b
6
0
0
0
0
b
5
0
0
1
1
b
4
0
1
0
1
= –
= –
= –
= 2 sec.
b
6
1
1
1
1
b
5
0
0
1
1
b
4
0
1
0
1
= 30 sec.
= –
= –
= 8 sec.