ND-70348 (E) CHAPTER 4
Page 174
Revision 3.0
ASYD
Note 1: Fixed to data “0” for 1-IMG system, whether the ATTCON is used or not.
Note 2: This data won’t be valid unless it has been assigned before the system initialization.
Note 3: Among the SMDR equipment that has the same IOC equipment number, double assignment of port is re-
jected.
Note 4: The ports to be designated by SYS-1, INDEX 288, 290, 292, and 294 are limited to those designated as
SMDR by AIOC.
Note 5: This data is assigned at the node to which SMDR with IOC interface is connected. In case SMDR is not
connected to the node, this data setting is fixed to “0”.
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
0 – 511
DATA
(DATA)
00 – FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
257
b
0
DLKC Circuit Card for Attendant Console (ATTCON)
0/1 = Not exist in system/Exist in system Notes 1, 2
b
1
~ b
7
Not used
258 00 Not used
287 00 Not used
1
288
b
0
Output Port for SMDR A Apparatus
When b
4
= 0 (IOC equipment No. 0)
b
0
= Port 0 b
1
= Port 1 b
2
= Port 2 b
3
= Port 3
When b
4
= 1 (IOC equipment No. 1)
b
0
= Port 4 b
1
= Port 5 b
2
= Port 6 b
3
= Port 7
“1” is to be assigned to each bit corresponding to the Port No.
Notes 3, 4, 5
b
1
b
2
b
3
b
4
b
5
Expanded SMDR Output for SMDR A Apparatus
0/1 = Out/In Service
0
b
6
Not used
0
b
7
289
b
0
Fault detection timer of SMDR A Value for
the first digit (min):
(0~9) Hex
A~F Hex: Not used
Timer value ranges
from 1 to 99 min-
utes.
00 Hex: Without
fault detection
Normally, Assign 00
Hex.
b
1
b
2
b
3
b
4
Fault detection timer of SMDR A Value for
the second digit (min):
(0~9) Hex
A~F Hex: Not used
b
5
b
6
b
7
290
b
0
Output Port for SMDR B Apparatus
When b
4
= 0 (IOC equipment No. 0)
b
0
= Port 0 b
1
= Port 1 b
2
= Port 2 b
3
= Port 3
When b
4
= 1 (IOC equipment No. 1)
b
0
= Port 4 b
1
= Port 5 b
2
= Port 6 b
3
= Port 7
“1” is to be assigned to each bit corresponding to the Port No.
Notes 3, 4, 5
b
1
b
2
b
3
b
4
b
5
Expanded SMDR Output for SMDR B Apparatus
0/1 = Out/In Service
0
b
6
Not used
0