ND-70348 (E) CHAPTER 4
Page 178
Revision 4.0
ASYD
Note 1:
Digits 0~9 are used with Index 17, b
5
.
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
0 – 511
DATA
(DATA)
00 – FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
1
308
0
b
0
CS Report Output Port Designation.
“1” is to be assigned to the bit corresponding to the Port Number of the IOC
Circuit Card.
b
1
= Port 1 b
5
= Port 5
b
2
= Port 2 b
6
= Port 6
b
3
= Port 3 b
7
= Port 7
b
4
= Port 4
b
1
b
2
b
3
b
4
b
5
b
6
b
7
309 00
Not used
310 00
Not used
311 00 Not used
320 00 Not used
321
b
0
Inter-Module Group Key Data 0/1 = No/Yes
b
1
Step Call While Transfer to Busy Station 0/1 = No/Yes
b
2
Termination on My Line 0/1: Not Restricted/Restricted
0
b
3
Not used
0
b
4
0
b
5
0
b
6
b
7
Voice Call Chime 0/1 = 4/1 Chime
322
b
0
Timing start to dial Attendant Console Assign digit used
Note 1
b
1
b
2
b
3
0
b
4
Not used
0
b
5
b
6
Tone to be heard after the access code for Tone Block is dialed
0/1 = SPDT/DT
0
b
7
Not used
323 00 Not used
367 00 Not used
368
0
b
0,
b
1
Not used
b
2
Alternate routing to No.7 CCIS line when a call to ISDN network (1st line)
is not available
0/1 = restricted/allowed
b
3
-
b
7
Not used
~
~
~
~
~
~
~