ND-70348 (E) CHAPTER 4
Page 186
Revision 3.0
ASYD
Note: b
0
. b
1
. and b
7
designate the type of sender signal for outgoing calls placed over routes programmed as
“DP/PB” via parameter ONSG (CDN: 2) of command “ARTD” (Route Class Data).
SYSTEM
DATA
TYPE
(SYS)
TENANT
NUMBER
(TN)
1 – 63
SYSTEM
DATA
INDEX
(INDEX)
0 –15
DATA
(DATA)
00 – FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
2
1
b
0
Call Transfer service
b
1
0
b
2
Not used
b
3
Toll Restriction for Speed Calling Station/Group services
0/1 = Required/Not Required
b
4
Toll Restriction (disposition of Restricted Call)
b
5
b
6
Speed Calling Override Service (via AABD)
0/1 = Out/In Service
b
7
Speed Calling Override Service (System basis)
0/1 = Follow RSC of Phone/Allowed
2
b
0
Sender Signal to DP/PB Route (Station) Note
0/1 = DP/PB
b
1
Sender Signal to DP/PB Route (Attendant Console)Note
0/1 = DP/PB
b
2
Attendant Console Day/Night Mode Change
b
3
0
b
4
Not used
b
5
Attendant Loop Release service
0/1 = Out/In Service
0
b
6
Not used
b
7
Kind of DP sender (when b
0
= 0) Note
0/1 = 10 PPS/20 PPS
SYSTEM TN
IMX 1 ~ 63
b
1
b
0
0 0 = Out of service
0 1 = In service – except Tandem Connection
1 0 = In service – only Terminating calls
1 1 = In service
b
5
b
4
0 0 = Toll Denial (ROT connection)
0 1 = Toll Diversion (Terminated to Attendant
Console)
10=
11=
b
3
b
2
0 0 = Not Required (External Switch effective)
0 1 = Master Attendant Console
1 0 = All Attendant Consoles
11=