ND-70348 (E) CHAPTER 4
Page 192
Revision 3.0
ASYD
SYSTEM
DATA
TYPE
(SYS)
TENANT
NUMBER
(TN)
1 – 63
SYSTEM
DATA INDEX
(INDEX)
0 – 15
DATA
(DATA)
00 – FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
210
0
b
0
Not used
0
b
1
0
b
2
0
b
3
b
4
Procedure for activating Call Waiting – Origi-
nating
0 = After hearing BT (SHF + ACC Code) only.
1 = After hearing BT (SHF + ACC Code) and
upon going Off-Hook (ACC Code + Station
No.).
Note: When activating this feature via dial-
ing ACC code + Station No., assign
the access code of Call Waiting-Orig-
inating by ASPA, CI = N.
0
b
5
Not used
b
6
Call Waiting-Terminating service (Automatic
setting of Call Waiting)
0/1 = Out/In Service
b
7
Call Waiting Tone
0/1 = Once/At Intervals
Note: When “1” is assigned, the interval of
this tone is assigned in SYS-1, INDEX
152.
SYSTEM TN
IMX 1 ~ 63