ND-70348 (E) CHAPTER 4
Page 354
Revision 3.0
AKYD_T
3. Data Entry Instructions
LN PRE
0 = Prime Line pickup
1 = Customize (Line
Preference data are to
be set for the other
buttons)
TP
DATA
MEANING
D
term
65 D
term
75
0
1
2
3
Note 2
Note 1
8-button or 16-button type
24-button type or 16-button type
with Add on Module
8/16-button type + FLEX keys
24-button type + FLEX keys or
16-button type with Add on Module
+ FLEX keys
8-button or 16-button type
32-button type (with Add on Module)
8/16-button type + FLEX keys
32-button type (with Add on Module)
+ FLEX Keys
MY LINE
PRIME LINE
USER
GROUP
NUMBER
(UGN)
USER GROUP
NUMBER
(PL UGN)
PRIORITY OF
ANSWERING
CALL
(PRI)
0-4
ALLOW OG
FROM
PRIME
LINE
(S)
0/1
MESSAGE
WAITING DATA
DISPLAY
SELECTION
(MWD)
0/1
TELEPHONE NUMBER
(TELN)
TELEPHONE NUMBER
(PL TELN)
LINE
PREFERENCE
(LN PRE)
0/1
TYPE OF
DTERM
(TP)
0-3
LINE
PREFERENCE
FOR SPEAKER
BUTTON
(SPK)
0-3
LINE
PREFERENCE
FOR ANSWER
BUTTON
(ANS)
0-2
LINE
PREFERENCE
FOR
OUT GOING
BUTTON
(ORG)
0/1
S
OFF-HOOK suppression
0=No 1=Yes
PRI
L: As per Preference pattern when
the SPEAKER button is pressed.
D: Dial Intercom Line
(Ringing Station)
A: Automatic Intercom Line
(Ringing Station)
M: Manual Intercom Line
(Signaling Station)
PRI
LINE PREFERENCE
1
L
D
A
M
A
2
L
L
L
M
3
L
0
1
2
3
4
ANS
This data is only available in case of LN PRE=1.
0 = Prime Line Preference
1 = Incoming Line Preference
2 = Ringing Line Preference
SPK
This data is only available in case of LN PRE =1
0 = Prime Line Preference
1 = Idle Line Preference
2 = Incoming Line Preference
3 = Ringing Line Preference
MWD
0 = MW data display on the top line
1 = MW data display on the bottom line
ORG
This data is only available in case of
LN PRE=1.
0 = Prime Line Preference
1 = Idle Line Preference
The data assigned to the parameter
TP may
differ depending on the parameter
KYI, or
KYI2. See the below.
Note 1: When no data is assigned to KYN2,
the system recognizes as TP=0.
Note 2: (1) When no data is assigned to
KYN=17 or later/KYN2, the sys-
tem recognizes as TP=0.
(2) When data is assigned to KYN=17
or later and no data is assigned to
KYN2, the system recognizes as
TP=1.

Table of Contents