ND-70348 (E) CHAPTER 4
Page 535
Revision 3.0
AUAD
3. Data Entry Instructions
NUMBER OF
ANNOUNCEMENT
TRUNK
(CNT)
1-8
CONTROLLING
STATION
ANNOUNCEMENT
TRUNK
TN and STN
DLYT
Enter the delay timer value in second with a range of 0-
30 seconds. (2 seconds increments)
TN and STN (UCD pilot station number) parameter should be assigned with respect to the TN and
STN data assigned by the ASHU command.
1
2
MSGT
RP
Announcement replay
0 = Once
1 = Repeat within the time specified by the INT parameter
INT
The INT parameter is appeared when RP = 1.
Enter the replay interval time value in second with a range
of 0-30 seconds. (2 seconds increments)
CNT
The number of external trunks to be connected an
external announcement machine.
DELAY
TIMER
(DLYT)
0-30
TRUNK
NUMBER
(TK)
ROUTE
NUMBER
(RT)
MESSAGE
TIMER
(MSGT)
0-30
ANNOUNCE-
MENT
OUTPUT
REPLAY
(RP)
0/1
REPLAY
INTERVAL
(INT)
0-30
TENANT
NUMBER
(TN)
STATION
NUMBER
(STN)
Enter the message timer value in second within 0-30 seconds.
(2 seconds increments)
However, this value is not effective if the Route data of Announcement
Trunk is assigned as follows,
ARTD ANS=1