EasyManuals Logo

NEC NEAX 7400 IMX User Manual

NEC NEAX 7400 IMX
857 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #636 background imageLoading...
Page #636 background image
ND-70348 (E) CHAPTER 4
Page 612
Revision 3.0
ACBC
3. Data Entry Instructions
ORDER OF
ROUTE
ADVANCING
(RA)
0-7
SERVICE
MODE
INTERFACE
TYPE
(INTF)
1/5/7/10
NUMBERING
PLAN
IDENTIFICA-
TION
(NPI)
0-15
LCR
CHANGE
PATTERN
(PNL)
1-999
TYPE OF
NUMBER
(TON)
0-7
FEATURE/
SERVICE
(SERV)
0-2
FACILITY
FAILURE
(CODE)
0-31
SCC
DISTINGUISH
NUMBER
(SCC)
MAX.4
DIGITS
TIME OF DAY
CHANGE
PATTERN
(TDPTN)
0-7
OUTGOING ROUTE
SELECTION PATTERN
NUMBER (OPR)
0-4095
TDPTN
OPR
SCC
NPI
SERV
TON
CODE
INTF
RA
Enter the route advancing order.
1=N-ISDN2
5=AT&T
7=Northern Telecom (NT)
10=Q-sig./IS11572
The different range of data can be entered
depending on the data of INTF/SERV
parameter. See Table 4-29 (Next Page) CODE for
applicable CODE data.
0=Unknown
1=International
2=National
3=Not used
4=Local
5-7=Not used
TDPTN is specified by the ATCP command
OPR is specified by the AOPR command
0=Unknown
1=ISDN/Telephony Numbering Plan
2-8=Not used
9=Private Network Numbering Plan
10-15=Not used
0=Feature
1=Service
2=SET TON&NPI
Enter SCC distinguish
number
Always assigned as "0."
0=Call by Call Service
MD
(MD)
CODING
VALUES
WATS
BAND
NUMBER
(BAND)
0-9
BAND
Enter WATS Band Number.
Enter the LCR Change Pattern within the range from 1 to 999. This parameter
is related to the PNL data assigned by the AOPR/AADC command.
PNL

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NEC NEAX 7400 IMX and is the answer not in the manual?

NEC NEAX 7400 IMX Specifications

General IconGeneral
BrandNEC
ModelNEAX 7400 IMX
CategoryServer
LanguageEnglish

Related product manuals