ND-70348 (E) CHAPTER 4
Page 627
Revision 3.0
ACTKC
3. Data Entry Instruction
Note 1: When “Delete” is selected in “KIND” box, the data for “C_RT”, “C_TK” and “STEP” is required.
Note 2: When the assignment/deletion is successful, “OK” is displayed in “STATUS” grid. Otherwise, related er-
ror message is provided.
CONNECTION
ROUTE
NUMBER
(C_RT)
1-1023
CONNECTION
TRUNK NUMBER
(C_TK)
1-4095
CONNECTION
EQUIPMENT
NUMBER
(C_LENS)
GROUP
NUMBER
(GROUP)
0-31
LEVEL
NUMBER
(LEVEL)
0-7
COUNT
UP
STEP
(STEP)
1-10
COUNT
UP
TYPE
(TYPE)
1-6
STATUS
STEP
Specify the interval between the consecutive connection
trunk numbers to be assigned/deleted.
Ex. C_TK (START)=1, STEP=3 is entered, connection
trunk number is assigned/deleted as follows;
[1, 4, 7, 10, 13, 16, ......]
LEVEL
Enter the first/last
level number.
START END START END START END START END
C_TK
The connection trunk controlled
by the connection route. Enter the
range of trunk numbers to be
assigned/deleted.
TYPE
This parameter determines how to
arrange the trunk data. Refer to the
next pages for more detail
explanation.
1: LEVEL
2: LEVEL
3: GROUP
4: GROUP
5: UNIT
6: UNIT
→
→
→
→
→
→
GROUP
UNIT
UNIT
LEVEL
LEVEL
GROUP
→
→
→
→
→
→
UNIT
GROUP
LEVEL
UNIT
GROUP
LEVEL
C_LENS
LENS of the trunk for B-
channel and D-channel.
C_RT
The route assigned for
B-channel and D-channel.
Enter the first/last
group number.
GROUP