ND-70348 (E) CHAPTER 4
Page 642-1
Revision 4.0
AGIP
IP ADDRESS
OF NTP
SERVER
(NTP_IP)
PKTLOSSRTP JIT_MAX JIT_MIN MNGS
JIT_COUNT
JIT_FAST TIME_FAST
BASE_COUNT
RTP
Check the “RTP” check box for detail assignment. (Usually default data “0” is set for all the parameters.)
PKGLOSS: Amount of Packet Loss [0%-100%] 0=8% (default)
JIT_MAX: Maximum Jitter Buffer [0-60 × 10ms] 0=600ms (default)
JIT_MIN: Minimum Jitter Buffer [0-60 × 10ms] 0=80ms (default)
MNGS: Interval of Jitter adjustment [0-255 times] 0=5 times (default)
JIT_COUNT: Interval of Jitter statistics [0-255 second] 0=1 second (default)
BASE_COUNT: Interval of Time-base correction [0-255 second] 0=10 second (default)
JIT_FAST: Judging rate of fast arrived packet [0-100%] 0=100% (default)
TIME_FAST: Time-base correction Judgment [0-100%] 0=50% (default)
Not used.
OPTION
OPTIONAL DATA
(OPTION)
[32 byte]