ND-70348 (E) CHAPTER 4
Page 664
Revision 3.0
ASYDN
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
0
1535
DATA
(DATA)
00
FF
(Hex)
BIT
CORRESPOND-
ING
DATA
SYSTEM DATA CONTENTS (MDATA)
DATA
0/1
BIT
1
67 00 Not used
68
b
0
Operating method for busy station service (Call back, Ex-
ecutive Right of Way, etc.,)
0/1 = SHF
×
Access Code / SHF
×
Access Code and Last Digit
×
Access Code
0
b
1
Not used
0
b
2
Not used
b
3
OG Trunk Queuing (On-Hook) Automatic Cancel
(for Netfusing Service)
0/1 = Out/In Service
0
b
4
Not used
0
b
5
Not used
0
b
6
Not used
0
b
7
Not used
69
0
b
0
Not used
0
b
1
0
b
2
0
b
3
0
b
4
b
5
Hunting Group when transferred party is busy (Station
Hunting after C.F. – Busy Line) (for Netfusing Service):
0 = Hunt in Transferring Party’s Group
1 = Hunt in Transferred Party’s Group
0
b
6
Not used
b
7
Multiple Call Forwarding – Busy Line/All Calls
(for Netfusing Service)
0/1 = Out/In Service