ND-70348 (E) CHAPTER 4
Page 711
Revision 3.0
AHSY
INDEX
(0 – 2047)
DATA
(DATA)
00 – FF
(Hex)
BIT
CORRESPONDING
DATA
CONTENTS
DATA
0/1
BIT
110
b
0
Room key Interface
0: Interface is absent (STAY/OUT is displayed)
1: Interface is present (Key status is displayed)
b
1
Attendant Console Guest Information Service
0/1 = Not Required/Required
0
b
2
Not used
b
3
Called Number Display on the Attendant Console
0/1 = Out/In Service
0
b
4
Not used0
b
5
0
b
6
b
7
Guest Name Display – D
term
, Guest Information Display – D
term
/PMS Termi-
nal Model 120
0/1 = Out/In Service
111
0
b
0
Fixed Data
0
b
1
b
2
Restriction for hooking when an outgoing C.O. line call has originated from a
suite room
0/1 = Restriction/No Restriction
b
3
Setting of Message Registration Data to be sent out to the PMS
b
4
b
3
0 0 : The pilot number is sent out for the Suite Room; the Main Room
Station Number is sent out for the Connecting Room.
0 1 : The station Number of each station within the room is sent out.
b
4
0
b
5
Fixed Data
0
b
6
b
7
Connecting Room
0/1 = Out/In Service