ND-70348 (E) CHAPTER 4
Page 789
Revision 3.0
AGST
3. Data Entry Instructions
TEC
LENS
Enter the LENS
XX X XX X
Level No. (0-7)
Group No. (00-31)
Unit No. (0-3)
Module Group No. (00-31)
G
0 : Ground
1 : Underground
TENANT
NUMBER
(TN)
STATION
NUMBER
(STN)
Max.6 digits
TELEPHONE
EQUIPMENT
CLASS
(TEC)
1-31
ROUTE
RESTRICTION
CLASS
(RSC)
0-15
SERVICE
FEATURE
CLASS
(SFC)
0-15
ROOM
CLASS
0-15
ANNEX
(ANX)
0-3
GROUND/
UNDERGROUND
(G)
0/1
FLOOR
(FLR)
1-127
LINE EQUIPMENT
NUMBER
(LENS)
MG U G LV
ANNEX
0 : Main Building
1 : Annex 1
2 : Annex 2
3 : Annex 3
RSC
Enter the RSC defined by the ARSC command. Since RSC = 0 is
preserved for ATTCON, a station can be used the RSC range from 1 to 15.
SFC
Enter the SFC defined by the ASFC command. Since SFC = 0 is
preserved for ATTCON, a station can be used the SFC range from 1 to 15.
Imput Data 0-15
Note: When the D
term
is used for Guest station,
ROOM CLASS is fixed to 15 .
Room Class
STN
Enter the station number with regard to the followings;
The number of station number (STN) digits is designated
by the ASYD command, SYS1, INDEX 16.
Example: 0=Single Room
1=Suite Room
1-4 : Not used
5 : DP (10pps)
6 : PB
7 : DP/PB
8 : DP (20pps) 9 : Not used
10 : House Phone 11 : Not used
12 : D
term
13-31 : Not Used

Table of Contents