FD 100/320Gbps NT and FX NT IHub Services Guide Services Overview
Issue: 13 3HH-11985-AAAA-TQZZA 93
 
3.17.4.14 measurement-period
Table 30 measurement-period command
3.17.4.15 mac-address
Table 31 mac-address command
3.17.4.16 type
Table 32 type command
Item Description
Syntax measurement-period period
Context configure>eth-cfm>y1731pm>domain
Description The value of measurement-period specifies the time after which the synthetic loss calculation 
is made periodically. If the value of this object is set to 'X' seconds, loss measurement 
calculations are done after every 'X' seconds. This includes the default SLM timeout of 5 
seconds in which the agent will   not transmit any further SLM PDUs and will wait for the 
response from   remote node. Upon the expiration of the timeout, the agent assumes that the 
message response will not be received. Any response received after the timeout    period has 
expired is silently discarded. This parameter is optional and is valid only if type – two-way-slm.
This can be set only when admin status is set to disabled.
The no form of the command reverts the value to the default.
Default 300 seconds
Parameters period — [60|300]
Item Description
Syntax mac-address mac-address
Context configure>eth-cfm>y1731pm>domain
Description Specifies the target unicast MAC address for the y1731pm session.
The no form of the command reverts the value to the default
Default 00:00:00:00:00:00
Parameters period — [xx:xx:xx:xx:xx:xx or xx-xx-xx-xx-xx-xx]
Item Description
Syntax type type
(1 of 2)