Remote Control Commands
R&S
®
SMW200A
1000User Manual 1175.6632.02 ─ 30
Parameters:
<Angle> float
Range: 0 to 180
Increment: 0.01
*RST: 0
Default unit: Deg
Example:
BB:DM:FORM AQPS
BB:DM:AQPS:ANGL 45
Manual operation: See "Angle Alpha" on page 273
[:SOURce<hw>]:BB:DM:ASK:DEPTh <Depth>
Sets the ASK modulation depth for modulation type ASK.
Parameters:
<Depth> float
Range: 0 to 100
Increment: 0.1
*RST: 100
Default unit: PCT
Example:
BB:DM:FORM ASK
BB:DM:ASK:DEPT 50 PCT
Manual operation: See "ASK Depth" on page 273
[:SOURce<hw>]:BB:DM:FSK:DEViation <Deviation>
Sets the frequency deviation when FSK modulation is selected.
Parameters:
<Deviation> float
The value range depends on the symbol rate.
Range: 1 to 40E6
Increment: 0.5
*RST: 135416.5
Example:
SOURce:BB:DM:FORMat FSK4
SOURce:BB:DM:FSK:DEViation 1MHZ
Manual operation: See "FSK Deviation" on page 273
[:SOURce<hw>]:BB:DM:FSK:VARiable:SYMBol<ch0>:DEViation <Deviation>
Sets the deviation of the selected symbol for variable FSK modulation mode.
SOURce Subsystem