EasyManua.ls Logo

Rohde & Schwarz R&S SMW200A - Page 1001

Rohde & Schwarz R&S SMW200A
1403 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Control Commands
R&S
®
SMW200A
1001User Manual 1175.6632.02 ─ 30
Parameters:
<Deviation> float
The value range depends on the selected symbol rate (see data
sheet).
Range: -40E6 to 40E6
Increment: 0.5
Default unit: Hz
Example:
SOURce:BB:DM:FORMat FSKVar
SOURce:BB:DM:FSK:VARiable:TYPE FSK4
SOURce:BB:DM:FSK:VARiable:SYMBol0:DEViation 135000
Manual operation: See "Deviation xxxx" on page 273
[:SOURce<hw>]:BB:DM:FSK:VARiable:TYPE <Type>
The command selects the modulation type for Variable FSK.
Parameters:
<Type> FSK4 | FSK8 | FSK16
*RST: FSK4
Example: See [:SOURce<hw>]:BB:DM:FSK:VARiable:
SYMBol<ch0>:DEViation on page 1000
Manual operation: See "FSK Type" on page 273
[:SOURce<hw>]:BB:DM:APSK16:GAMMa <Gamma>
Sets the gamma function γ for the 16APSK modulation.
Parameters:
<Gamma> G2D3 | G3D4 | G4D5 | G5D6 | G8D9 | G9D10
GxDy: G = Gamma function, xy = code rate
*RST: G2D3
Example:
SOURce1:BB:DM:FORMat APSK16
SOURce1:BB:DM:APSK16:GAMMa G9D10
Manual operation: See "Gamma/Gamma 1" on page 274
[:SOURce<hw>]:BB:DM:APSK32:GAMMa <Gamma>
Sets the gamma function γ for the 32APSK modulation.
Parameters:
<Gamma> G3D4 | G4D5 | G5D6 | G8D9 | G9D10
GxDy: G = Gamma function, xy = code rate
*RST: G3D4
SOURce Subsystem

Table of Contents