Remote Control Commands
R&S
®
SMW200A
1059User Manual 1175.6632.02 ─ 30
[:SOURce<hw>]:BB:ONEWeb:NOTCh <NotchState>
[:SOURce<hw>]:BB:ARBitrary:NOTCh <NotchState>
Enables or disables the notch filter.
Parameters:
<NotchState> 0 | 1 | OFF | ON
*RST: 0
Example: See Example "Creating notch filter" on page 1028.
Manual operation: See "State" on page 347
[:SOURce<hw>]:BB:DVB:NOTCh:CLOCk?
[:SOURce<hw>]:BB:EUTRa:NOTCh:CLOCk?
[:SOURce<hw>]:BB:OFDM:NOTCh:CLOCk?
[:SOURce<hw>]:BB:ONEWeb:NOTCh:CLOCk?
[:SOURce<hw>]:BB:ARBitrary:NOTCh:CLOCk?
Queries the current clock frequency of the waveform signal.
Works like the command [:SOURce<hw>]:BB:ARBitrary:CLOCk.
Return values:
<ChBw> integer
Range: 400 to 2000E6
*RST: 1E6
Example: See Example "Creating notch filter" on page 1028.
Usage: Query only
Manual operation: See "Clock Frequency" on page 347
[:SOURce<hw>]:BB:DVB:NOTCh:COUNt <NumOfNotch>
[:SOURce<hw>]:BB:EUTRa:NOTCh:COUNt <NumOfNotch>
[:SOURce<hw>]:BB:OFDM:NOTCh:COUNt <NumOfNotch>
[:SOURce<hw>]:BB:ONEWeb:NOTCh:COUNt <NumOfNotch>
[:SOURce<hw>]:BB:ARBitrary:NOTCh:COUNt <IdPDbNotchedNum>
Sets the number of notches.
Parameters:
<IdPDbNotchedNum>integer
Range: 1 to 25
*RST: 1
Example: See Example "Creating notch filter" on page 1028.
Manual operation: See "Number of Notches" on page 348
[:SOURce<hw>]:BB:DVB:NOTCh<ch>:STATe <ValEnable>
[:SOURce<hw>]:BB:EUTRa:NOTCh<ch>:STATe <NotchState>
[:SOURce<hw>]:BB:OFDM:NOTCh<ch>:STATe <NotchValEnable>
SOURce Subsystem