Remote Control Commands
R&S
®
SMW200A
1096User Manual 1175.6632.02 ─ 30
[:SOURce<hw>]:AWGN:POWer:CARRier <Carrier>
Sets the carrier power.
Parameters:
<Carrier> float
Increment: 0.01
*RST: 0
Example: see Example "Generating an additive noise signal"
on page 1091
Manual operation: See "Carrier Power, Signal Power" on page 428
[:SOURce<hw>]:AWGN:POWer:NOISe <Noise>
Sets the power of the noise signal in the system respectively total bandwidth.
Parameters:
<Noise> float
Increment: 0.01
Example: see Example "Generating an additive noise signal"
on page 1091
Manual operation: See "Noise Power (System Bandwidth), Interferer Power"
on page 428
[:SOURce<hw>]:AWGN:POWer:NOISe:TOTal?
Queries the noise level in the total bandwidth.
Return values:
<Total> float
Range: -145 to 20
Increment: 0.01
*RST: -30
Example: see Example "Generating an additive noise signal"
on page 1091
Usage: Query only
Manual operation: See "Noise Power (Total Bandwidth)" on page 429
[:SOURce<hw>]:AWGN:POWer:SUM?
Queries the overall power of the noise/interferer signal plus useful signal