Remote Control Commands
R&S
®
SMW200A
1235User Manual 1175.6632.02 ─ 30
:SYSTem:SECurity:SANitize[:STATe] <SecPassWord>, <MmemProtState>
Sanitizes the internal memory.
Parameters:
<MmemProtState> 0 | 1 | OFF | ON
*RST: 0
Setting parameters:
<SecPassWord> string
Example:
SYSTem:SECurity:SANitize[:STATe] 1
Manual operation: See "Sanitize" on page 757
:SYSTem:SECurity:SUPolicy
<SecPassWord>, <UpdatePolicy>
Configures the automatic signature verification for firmware installation.
Parameters:
<UpdatePolicy> STRict | CONFirm | IGNore
*RST: n.a. (factory preset: CONFirm)
Setting parameters:
<SecPassWord> string
Manual operation: See "Secure Update Policy" on page 755
:SYSTem:SPECification? <Id>
Retrieves data sheet information for a specific parameter.
Setting parameters:
<Id> string
Identifies the name of the entry in the data sheet, as quieried
with the command :SYSTem:SPECification:
IDENtification:CATalog? on page 1236
Return values:
<ValList> float
Comma-separated list with the specified and, if available, the
typical value of the parameter, as specified in the data sheet.
SYSTem Subsystem