Signal Routing and System Configuration
R&S
®
SMW200A
207User Manual 1175.6632.02 ─ 30
Figure 4-29: Example of test setup*: 8x8 MIMO with 2xR&S
SMW and 4xR&S
SGT
blue circle = front panel connector
gray circle = rear panel connector
* = To simplify the diagram, it does not show the LAN/USB connections between the instruments
Workflow overview
1. Cabling
See "To cable the instruments" on page 208.
2. Configuring the first R&S SMW
See "To configure the R&S SMW that simulates the first subset" on page 208.
3. Configuring the second R&S SMW
See "To configure the R&S SMW that simulates the second subset" on page 209.
4. Starting signal generation
How to Connect External Instruments and Configure the Signal Flow