Remote Control Commands
R&S
®
SMW200A
907User Manual 1175.6632.02 ─ 30
Example: Configuring primary-secondary mode
// For the primary instrument:
SOURce1:ROSCillator:SOURce INT
SCONfiguration:MULTiinstrument:MODe PRIMary
SCONfiguration:MULTiinstrument:STATe 1
SCONfiguration:APPLy
SOURce1:INPut:USER6:DIRection OUTP
OUTPut1:USER6:SIGNal INSinc
SOURce1:INPut:USER5:DIRection OUTP
OUTPut1:USER5:SIGNal INSinc
// For the secondary instrument:
SOURce1:ROSCillator:SOURce EXT
SOURce1:ROSCillator:EXTernal:FREQuency 10MHZ
SCONfiguration:MULTiinstrument:MODe SECondary
SCONfiguration:MULTiinstrument:STATe 1
SOURce1:INPut:USER5:DIRection INP
SOURce1:INPut:USER5:SIGNal OUTSinc
SOURce1:INPut:USER6:DIRection OUTP
OUTPut1:USER6:SIGNal INSinc
SCONfiguration:MULTiinstrument:TRIGger:SYNChronization?
// SYNC
Example: Generating digital signals
SCONfiguration:PRESet
SCONfiguration:MODE ADVanced
SCONfiguration:OUTput:MODE HSAL
SCONfiguration:FADing FAAFBB
SCONfiguration:BASeband:SOURce SEP
SCONfiguration:DIQ:BBMM1:CHANnels CH6
SCONfiguration:DIQ:BBMM2:CHANnels CH4
SCONfiguration:DIQ:BBMM1:CHANnels?
// CH4
// number of channels adapted so that the total number of channels is 8
SCONfiguration:APPLy
See also Example "Enabling and configuring the HS DIG I/Q digital outputs"
on page 1144.
Example: Generating digital multiplexed signals
The following is a general example. Not all required settings are considered.
// ******************************************************************
// Reset the system configuration and enable a 1x2x8 MIMO fading config
SCONfiguration:PRESet
SCONfiguration:MODE ADVanced
SCONfiguration:FADing MIMO2X8
SCONfiguration Subsystem