Remote Control Commands
R&S
®
SMW200A
995User Manual 1175.6632.02 ─ 30
[:SOURce<hw>]:BB:DM:SMODulation:CLOCk:SLOPe:BIT <Slope>
Sets the active edge of the bit clock.
Parameters:
<Slope> NEGative | POSitive
*RST: POSitive
Example: See [:SOURce<hw>]:BB:DM:SMODulation:BORDer
on page 994
Options: R&S SMW-B10
Manual operation: See "Bit Clock Slope" on page 270
[:SOURce<hw>]:BB:DM:SMODulation:THRoughput:DELay?
Queries the throughput delay from the data input to the RF output in the case of exter-
nal modulation.
Return values:
<Delay> integer
Range: -100 to 100
Increment: 250E-12
*RST: 0
Example: See [:SOURce<hw>]:BB:DM:SMODulation:BORDer
on page 994.
Usage: Query only
Manual operation: See "Throughput Delay" on page 270
[:SOURce<hw>]:BB:DM:SMODulation:RCVState? <RcvState>
Queries the current state of the receiver of the external data.
Parameters:
<RcvState> OFF | OPERational | UFLow | OFLow
*RST: OFF
Example: See [:SOURce<hw>]:BB:DM:SMODulation:BORDer
on page 994.
Usage: Query only
Manual operation: See "Receiver State" on page 269
SOURce Subsystem