[:SOURce<hw>]:BB:DM:PRBS[:LENGth] <Length>
Defines the length of the pseudo-random sequence in accordance with the following
equation:
Length = (2^Length) - 1
Parameters:
<Length> 9 | 11 | 15 | 16 | 20 | 21 | 23 | PN9 | PN11 | PN15 | PN16 | PN20 |
PN21 | PN23
*RST: 9
Example: See Example "Performing general tasks" on page 989
Manual operation: See "Data Source" on page 267
[:SOURce<hw>]:BB:DM:SMODulation:BORDer
<BitOrder>
Sets the bit order for processing extern serial data.
Parameters:
<BitOrder> LSBit | MSBit
*RST: LSBit
Example:
SOURce1:INPut:TM1:DIRection INP
SOURce1:INPut:TM1:SIGNal CLOCk
SOURce1:INPut:TM2:DIRection INP
SOURce1:INPut:TM2:SIGNal DATA
SOURce1:BB:DM:SOURce SERial
SOURce1:BB:DM:SMODulation:BORDer LSBit
SOURce1:BB:DM:SMODulation:CDTDeviation?
SOURce1:BB:DM:SMODulation:CLOCk:SLOPe:BIT POSitive
SOURce1:BB:DM:SMODulation:THRoughput:DELay?
SOURce1:BB:DM:SMODulation:RCVState?
// Response: OPERational
Manual operation:
See "Bit Order" on page 270
[:SOURce<hw>]:BB:DM:SMODulation:CDTDeviation <Deviation>
Queries the timing deviations (time offset) between the clock and the data signals.
Parameters:
<Deviation> float
Range: -5E-3 to 5E-3
Increment: 1E-12
*RST: 0
Example: See [:SOURce<hw>]:BB:DM:SMODulation:BORDer
on page 994.
Manual operation: See "Clock to Data Time Deviation" on page 270