Remote Control Commands
R&S
®
SMW200A
993User Manual 1175.6632.02 ─ 30
Parameters:
<Standard> USER | BLUetooth | DECT | ETC | GSM | GSMEdge | NADC |
PDC | PHS | TETRa | W3GPp | TDSCdma | CFORward |
CREVerse | WORLdspace | TFTS | APCOPH1C4fm |
APCOPH1CQpsk | APCOPH2HCpm | APCOPH2HDQpsk |
APCOPH2HD8PSKW | APCOPH2HD8PSKN | APCOPH1Lsm |
APCOPH1Wcqpsk | CWBPsk
A query returns the value USER if one the following is true:
• A user-defined custom digital modulation setting was loaded
• One of the associated settings was changed subsequent to the
selection of a standard.
*RST: GSM
Example: See Example "Performing general tasks" on page 989
Options: GSM requires R&S SMW-B10
Manual operation: See "Set according to Standard" on page 264
[:SOURce<hw>]:BB:DM:SOURce
<Source>
Selects the data source.
Parameters:
<Source> ZERO | ONE | PRBS | PATTern | DLISt | SERial
A sequence of 0 or 1, a pseudo-random sequence with different
length, a pattern, a data list, or external serial data.
*RST: PRBS
Example: See Example "Performing general tasks" on page 989
Manual operation: See "Data Source" on page 267
[:SOURce<hw>]:BB:DM:PATTern <Pattern>, <BitCount>
Selects the data pattern for the internal data source.
Parameters:
<Pattern> numeric
*RST: #H0
<BitCount> integer
Range: 1 to 64
*RST: 1
Example:
SOURce:BB:DM:SOURce PATT
SOURce:BB:DM:PATTern #B01110111010101010,17
Generates the user-defined sequence of 0/1 data.
Manual operation: See "Data Source" on page 267
SOURce Subsystem