Remote control commands
R&S
®
RTM3000
470User Manual 1335.9090.02 ─ 09
17.5.6.2 Time limitation
TRIGger:A:PATTern:MODE............................................................................................. 470
TRIGger:A:PATTern:WIDTh:RANGe.................................................................................470
TRIGger:A:PATTern:WIDTh[:WIDTh]................................................................................ 470
TRIGger:A:PATTern:WIDTh:DELTa.................................................................................. 471
TRIGger:A:PATTern:MODE <PatternMode>
Disables the time limitation or sets the time comparison mode.
Parameters:
<PatternMode> OFF | TIMeout | WIDTh
OFF
Disables the time limitation.
TIMeout
Defines how long at least the result of the state pattern condition
must be true or false.
WIDTh
Defines a time range for keeping up the true result of the pattern
condition. The range is defined using TRIGger:A:PATTern:
WIDTh:RANGe.
TRIGger:A:PATTern:WIDTh:RANGe <PatternRange>
Selects how the time limit for the pattern condition is defined.
The time is specified using TRIGger:A:PATTern:WIDTh[:WIDTh], the range
around is specified using TRIGger:A:PATTern:WIDTh:DELTa.
Parameters:
<PatternRange> WITHin | OUTSide | SHORter | LONGer
WITHin
Triggers if the pattern condition remains unchanged longer than
Time - Delta and shorter than Time + Delta.
OUTSide
Triggers if the pattern condition remains unchanged either
shorter than Time - Delta or longer than Time + Delta.
SHORter | LONGer
Triggers if the pattern condition changes before or after the
specified time.
TRIGger:A:PATTern:WIDTh[:WIDTh] <PatternWidth>
For the ranges WITHin and OUTSide, the <PatternWidth> defines the center of a
range which is defined by the limits ±<Delta>.
For the ranges SHORter and LONGer, the pattern width defines the maximum and
minimum values, respectively.
Trigger