Remote control commands
R&S
®
RTM3000
555User Manual 1335.9090.02 ─ 09
SPECtrum:MARKer:RESult<n>:ALL:DELTa?
Returns the delta frequency and delta level, the difference between the freqeuncy/level
of the specified marker and the freqeuncy/level of the reference marker.
Suffix:
<n>
.
*
Return values:
<ResultValues> List of numeric values with shape <freq>,<level>,....
Usage: Query only
SPECtrum:MARKer:RESult<n>:DELTa?
Returns the difference in the values between the n-th marker and the reference
marker.
Suffix:
<n>
.
*
Usage: Query only
SPECtrum:MARKer:RESult<n>:FREQuency?
Returns the frequency of the n-th marker.
Suffix:
<n>
.
*
Return values:
<ResultFrequency>
Usage: Query only
SPECtrum:MARKer:RESult<n>:FREQuency:DELTa?
Returns the delta frequency, the difference between the frequency of the specified
marker and the level of the reference marker.
Suffix:
<n>
.
*
Return values:
<ResultFrequencyDifference>
Usage: Query only
SPECtrum:MARKer:RESult<n>:LEVel?
Returns the level of the n-th marker.
Suffix:
<n>
.
*