Remote control commands
R&S
®
RTM3000
733User Manual 1335.9090.02 ─ 09
POWer:MODulation:RESult:MEAN:PPEak?
POWer:MODulation:RESult:MEAN:STDDev?
POWer:MODulation:RESult:MEAN:WFMCount?
Returns the corresponding statistic result for "Mean".
●
[:ACTual]: current measurement result
●
AVG: average of the long-term measurement results
●
NPEak: negative peak value of the long-term measurement results
●
PPEak: positive peak value of the long-term measurement results
●
STDDev: standard deviation of the long-term measurement results
●
WFMCount: the number of waveforms used for the displayed results
Return values:
<WaveformCount>
Usage: Query only
POWer:MODulation:RESult:RMS[:ACTual]?
POWer:MODulation:RESult:RMS:AVG?
POWer:MODulation:RESult:RMS:NPEak?
POWer:MODulation:RESult:RMS:PPEak?
POWer:MODulation:RESult:RMS:STDDev?
POWer:MODulation:RESult:RMS:WFMCount?
Returns the corresponding statistic result for RMS.
●
[:ACTual]: current measurement result
●
AVG: average of the long-term measurement results
●
NPEak: negative peak value of the long-term measurement results
●
PPEak: positive peak value of the long-term measurement results
●
STDDev: standard deviation of the long-term measurement results
●
WFMCount: the number of waveforms used for the displayed results
Return values:
<WaveformCount>
Usage: Query only
POWer:MODulation:RESult:STDDev[:ACTual]?
POWer:MODulation:RESult:STDDev:AVG?
POWer:MODulation:RESult:STDDev:NPEak?
POWer:MODulation:RESult:STDDev:PPEak?
POWer:MODulation:RESult:STDDev:STDDev?
POWer:MODulation:RESult:STDDev:WFMCount?
Returns the corresponding statistic result for the standard deviation.
●
[:ACTual]: current measurement result
●
AVG: average of the long-term measurement results
Power analysis (option R&S