Remote control - basics
R&S
®
RTM3000
807User Manual 1335.9090.02 ─ 09
Allowed parameters are:
Numeric values..................................................................................................... 807
Special numeric values......................................................................................... 807
Boolean parameters..............................................................................................808
Text parameters.................................................................................................... 808
Character strings...................................................................................................808
Block data............................................................................................................. 809
A.1.3.1 Numeric values
Numeric values can be entered in any form, i.e. with sign, decimal point and exponent.
Values exceeding the resolution of the instrument are rounded up or down. The man-
tissa may comprise up to 255 characters, the exponent must lie inside the value range
-32000 to 32000. The exponent is introduced by an "E" or "e". Entry of the exponent
alone is not allowed.
Example:
SENS:FREQ:STOP 1500000 = SENS:FREQ:STOP 1.5E6
Units
For physical quantities, the unit can be entered. If the unit is missing, the basic unit is
used. Allowed unit prefixes are:
G (giga)
MA (mega), MOHM, MHZ
K (kilo)
M (milli)
U (micro)
N (nano)
Example:
SENSe:FREQ:STOP 1.5GHz = SENSe:FREQ:STOP 1.5E9
Some settings allow relative values to be stated in percent. According to SCPI, this unit
is represented by the PCT string.
Example:
HCOP:PAGE:SCAL 90PCT
A.1.3.2 Special numeric values
The following mnemonics are special numeric values. In the response to a query, the
numeric value is provided.
MIN and MAX: denote the minimum (MINimum) and maximum (MAXimum) value.
DEF: denotes a preset value (DEFault) which has been stored in the EPROM. This
value conforms to the default setting, as it is called by the *RST command.
SCPI command structure

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rohde & Schwarz RTM3K-COM2 and is the answer not in the manual?

Rohde & Schwarz RTM3K-COM2 Specifications

General IconGeneral
BrandRohde & Schwarz
ModelRTM3K-COM2
CategoryTest Equipment
LanguageEnglish

Related product manuals