M5: Measurement
7.4 Axial measurement
Extended Functions
450 Function Manual, 03/2013, 6FC5397-1BP40-3BA1
Two measuring systems
If the measuring job is performed with two measuring systems, a maximum of two trigger
events can be programmed. The measured values of both probes are acquired for each of
the two probes.
One trigger event
$AA_MM1[axis] = trigger event 1, measured value from encoder 1
$AA_MM2[axis] = trigger event 1, measured value from encoder 2
Two trigger events
$AA_MM1[axis] = trigger event 1, measured value from encoder 1
$AA_MM2[axis] = trigger event 1, measured value from encoder 2
$AA_MM3[axis] = trigger event 2, measured value from encoder 1
$AA_MM4[axis] = trigger event 2, measured value from encoder 2
PLC service display
For further information about the functional test of the probe, see Section "Measurement
results (Page 445)".
Read measurement results of MEAC
All measurements are written to a previously defined FIFO variable. The possible number of
measured values is defined via the machine data (see Section "Measurement (Page 446)").
The co
rrect operation is executed reliably for PROFIBUS telegram 391 for the ratios of
the IPO clock / position controller cycle ≤ 8:1.
The correct operation is executed reliably for PROFIBUS telegram 395 for the ratios of
the IPO clock / position controller cycle ≤ 4:1.
The contents of the FIFO memory can be read only once. When measurement results are
used more than once, the read-out values must be buffered in the user data.
Endless measuring
In order to implement endless measuring, FIFO values must be read cyclically from the part
program. The frequency with which the measured values are read from the FIFO memory
and processed must correspond to the writing frequency of the NC.
The number of valid entries is readable in a FIFO variable.
If measuring is to be terminated after reaching a defined number of measured values, the
measurement job must explicitly be deselected in the program.

Table of Contents

Other manuals for Siemens SINUMERIK Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK Series and is the answer not in the manual?

Siemens SINUMERIK Series Specifications

General IconGeneral
Axes ControlUp to 31 axes
CategoryControl Unit
ManufacturerSiemens
SeriesSINUMERIK
Control TypeCNC
Communication InterfacesEthernet, USB
Operating Temperature0°C to 45°C
Protection ClassIP20
Power Supply24V DC
DisplayColor TFT LCD

Related product manuals